Unconventional Reservoir Protection Instrument

Unconventional Reservoir Protection Instrument


The unconventional reservoir protection instrument can conduct reservoir damage evaluation experiments under simulated formation pressure and temperature conditions, especially simulating high temperature (180°C), high pressure (70MPa), and ultra-low permeability reservoirs (0.00001×10^-3 μm²). It can also perform experiments under strong acid and strong alkali conditions, including: (1) gas and liquid permeability measurement experiments; (2) reservoir damage evaluation experiments, studying the interaction between working fluids such as drilling fluid, completion fluid, and fracturing fluid with the reservoir during wellbore circulation, and the damage caused to the reservoir. It can simulate the shear of working fluids in the wellbore and measure fluid loss, studying the depth of damage. The following parameters can be measured: fluid loss, initial permeability, restored permeability, permeability damage rate, etc.; (3) sensitivity evaluation experiments including rapid sensitivity, water sensitivity, acid sensitivity, alkali sensitivity, salt sensitivity, stress sensitivity, and temperature sensitivity tests; (4) fracture plugging simulation experiments.
Contact Us

 


--------

High Precision

 

Operating Temperature: Room Temperature to 180℃

Temperature Control Accuracy: ±1℃

 


--------

Convenient and Easy to Use

 

Graphical User Interface

Easy and Understandable Operation


--------

Reliable and Stable

 

High Accuracy, High Stability

 

 


--------

Personalized Customization

 

Can be Customized According to Needs

Upgrade Equipment Configuration

     

 

Application Fields

 

 

Application Functions

Product Parameters

Parameter Indicators

Operating Temperature Room temperature ~ 180℃, temperature control accuracy: ±1℃
Confining Pressure 70MPa
Back Pressure 40MPa
Constant Flow and Constant Pressure Pump

Flow rate: 0.01~60.00 ml/min;

Pressure: 70 MPa, pressure test accuracy: 0.1% F·S;

Experiments can be conducted through software control of sinusoidal loading and constant flow and constant pressure mode loading

Dynamic Filtration Loss Clamp φ25.4×100mm, with 1 pressure measurement point
Fracture Sealing Visualization Module Adjustable fracture width 0~4mm, fracture length 80mm, pressure resistance 40 MPa
Material 316L Stainless Steel
Core Permeability Test Range (Steady-State Method)

Liquid phase: (1×10 -5 ~3000)×10 -3 μm 2

Gas phase: (0.01~6000)×10 -3 μm 2