Large-aperture Nuclear Magnetic Resonance Imaging Analyzer

Large-aperture Nuclear Magnetic Resonance Imaging Analyzer


Image signal-to-noise ratio ≥ 20dB, image distortion ≤ 5%, image uniformity ≥ 70%; Magnetic resonance analysis software includes multiple pulse sequences such as Fid, SE, IR, SR, CPMG, IR-CPMG, SR-CPMG, SFG-CPMG. The shortest CPMG echo time for a 1-inch probe is ≤ 60μs, with the probe featuring low heating technology; the shortest CPMG echo time for a 4-inch probe is ≤ 250μs, also with low heating technology. The device is equipped with RF technology to shorten probe dead time and capture shorter relaxation signals; it can be matched with low-temperature high-pressure modules (-30°C, 40MPa), high-temperature high-pressure modules (150°C, 80MPa), rock triaxial damage systems (axial pressure 100MPa), and other modules, supporting customer customization needs.
Contact Us


--------

Convenient and easy to use

 

Graphical user interface

Easy and understandable operation


--------

Reliable and stable

 

High accuracy, high stability

 

 


--------

Personalized customization

 

Can be customized according to needs

Enhance device configuration

     

Application Fields

 

Application Functions

Product Parameters

Parameter Indicators

   
Magnetic Field Strength

0.3±0.03T

Magnet Type

Permanent magnet, uniform magnetic field region: 300mm diameter sphere;

Magnetic Field Stability ≤300Hz/Hour
Magnetic Field Uniformity

≤50ppm (within uniform region)

Magnet Temperature

Nonlinear precise constant temperature control,

Adjustable within 25-35℃ range,

Temperature control accuracy resolution better than ±0.03℃

Frequency Source

Pulse frequency range 1-30MHz;

RF Transmission Power

Peak output ≥300W

High-density Integrated Single-board Spectrometer

USB Interface

Maximum Sampling Bandwidth

≥2000kHz

Parameter Indicators

   
Sampling Rate

50MHz, phase control accuracy ≤0.1 degree, Timing resolution ≤10ns, Frequency resolution ≤0.0000007Hz

CPMG Echo Number

≥50000, supports arbitrary echo number acquisition mode, Capable of simultaneously acquiring nano-scale pore fluid and free fluid signals

Imaging Gradient and Strength X, Y, Z three-dimensional independent gradients
Nuclear Magnetic Resonance Imaging Software

Supports 2D SE, HSE, SPRITE; 3D HSE, Conical and other imaging sequences

Various specifications of room temperature probes

One set of probes accommodating 1-inch core; One set of probes accommodating 1.5-inch core;

One set of probes accommodating 2-inch core; One set of probes accommodating 3-inch core;

One set of probes accommodating 4-inch core;

Various specifications of room temperature probes

One set of probes with inner diameter 150mm±2%; One set of probes with inner diameter ≥300mm±2%

Constant Gradient

Constant gradient in Y direction (displacement direction), 200A current, equipped with water cooling module;

Small Constant Gradient

Gradient plate spacing ≥86mm, gradient peak value: ≥30 Gauss/cm (300 mT/m);

Large Constant Gradient

Gradient plate spacing ≥150mm; peak value: ≥10 Gauss/cm (100 mT/m);

 