Continuous Supercritical Reaction Device

Continuous Supercritical Reaction Device


The continuous supercritical reaction experimental device is used for the supercritical water lightening of heavy hydrocarbons (plastics or crude oil). Its basic structure and functions comply with the requirements. Through a powder water suspension feeder and a liquid feed pump, plastic powder, crude oil, water, carbon dioxide, and other materials are pressurized and continuously delivered to the preheater. After being preheated to the set temperature, they enter the reactor to undergo the supercritical lightening reaction. The reaction process can be observed through a visual supercritical water reaction viewer. After cooling, the reaction products enter the product separator, where they are separated into gas, oil, and water. The gas is treated and then discharged through the exhaust system. The oil is sent to a simulated cracking experimental device as cracking feedstock. The water is collected centrally and sent for treatment of three wastes. Samples of each phase product are taken for analysis.
Contact Us


--------

Convenient and easy to use

 

Graphical user interface

Easy and understandable operation


--------

Reliable and stable

 

High accuracy, high stability

 

 


--------

Personalized customization

 

Can be customized according to needs

Enhance device configuration

     

Application Fields

 

Application Functions

Product Parameters

Parameter Indicators

Reactor Maximum Operating Temperature: 500℃, Maximum Operating Pressure: 40MPa
Fine Tube Reactor: Volume 2L, Inner Diameter 12mm, Length 18m
Coarse Tube Reactor: Volume 2L, Inner Diameter 40mm, Inner Height 1593mm, Outer Dimensions Approximately 1750mm
Visual Supercritical Water Reaction Observer Maximum Operating Temperature: 500℃
Maximum Operating Pressure: 40MPa
3. Powder Water Suspension Feeder
Used for pressurizing and conveying plastic powder; Volume 1000ml
Maximum Operating Pressure: 40MPa
Maximum Flow Rate: Powder 100g/h, Water 500g/h
Flow Control Accuracy: ±1%
Liquid Feed Pump Maximum Operating Pressure: 40MPa
Maximum Feed Rate: 10ml/min
Flow Control Accuracy: ±1%
Automatic Back Pressure Valve Maximum Operating Pressure: 41.5MPa
Pressure Control Accuracy: ±0.1MPa
Material Resistant to Oil and Carbon Dioxide
Product Separator Maintains a stable three-phase interface, for continuous metering of the extracted three phases