High-temperature and high-pressure shale dynamic imbibition evaluation device

High-temperature and high-pressure shale dynamic imbibition evaluation device


This device can simulate the throughput and seepage oil recovery process similar to the on-site seepage development process under the conditions of reproducing the in-situ high temperature and high pressure of tight reservoirs and shale oil reservoirs, and ensure accurate measurement of oil production, thereby providing important data support for determining the recoverable reserves of shale oil and tight oil, preparing development plans, and reservoir numerical simulation work.
Contact Us


--------

Convenient and easy to use

 

Graphical user interface

Easy and understandable operation


--------

Reliable and stable

 

High accuracy, high stability

 

 


--------

Personalized customization

 

Can be customized according to needs

Enhance device configuration

     

Application Fields

 

 

Application Functions

Product Parameters

Parameter Indicators

High-precision constant speed and constant pressure pump

The experimental displacement pump is a double-cylinder, pulse-free high-precision metering pump with a maximum injection pressure of 70MPa,

Flow accuracy 0.0001 ml/min; flow range: 0~20 ml/min

Nuclear Magnetic Resonance High-pressure Dynamic Imbibition System Rock sample specifications: diameter 25mm; sample length 100mm;
Operating temperature: room temperature ~150℃, temperature control accuracy: ±0.1℃
Operating pressure: sealed pressure resistance 42MPa
Full-diameter High-temperature High-pressure Dynamic Imbibition System

Rock sample specifications: Φ 120mm; sample length 200mm,

Equipped with point-contact clamping structure for rock samples, contact area 1cm², total dead volume 0.05ml,

Operating temperature: room temperature ~150℃, temperature control accuracy: ±0.1℃
Operating pressure: sealed pressure resistance 40MPa
High-temperature High-pressure Imbibition Distance Testing System Rock sample specifications: Φ 25mm; sample length 100mm
Operating temperature: room temperature ~160℃
Operating pressure: sealed pressure resistance 40MPa
Constant Temperature Control System Stainless steel inner liner, external baking finish, built-in lighting, front and rear double doors with full viewing windows
Room temperature ~160℃, accuracy ±0.5℃; dimensions: 1400mm×700mm×800mm